美国Teledyne 氧气传感器选型表


成都聚飞科技有限责任公司代理销售美国Teledyne公司原装进口的氧气传感器,也叫燃料电池,特价现货供应美国Teledyne Analytical Instruments 各种型号氧气传感器。


RANGE BACKGROUND GAS TELEDYNE INSTRUMENTS SENSOR OPTIONS
Trace Less than 1000 ppm CO2 in the background gas 311, 316, 317, 318, 3160 B-2C
3000T series L-2C
More than 1000 ppm up to 100% CO2 in the background gas All trace oxygen instruments A-2C
Note: To use the A-2C or B-2C sensor in a 3000T series instrument, adapter part number B66378 is required.
Note: The L-2C sensor cannot be used in our older analog models (300 series).
Percent Less than 1000 ppm CO2 in the background gas 311P, 320A / P / BRC, 326, 327, 328 B-1, B-3 standard;
C-3 for high concentration of O2
More than 1000 ppm up to 100% CO2 in the background gas A-5


Selecting a Teledyne Oxygen Sensor - Detail

CLASS
(click for spec control drwg.)
PART No. APPLICATION COMMENTS
A-1
oxygen sensor
C6689-A1 Ultra-fast response (90% in less than 4 seconds) in the percent oxygen region. Use only when B-1 response time is insufficient.
A-2C
oxygen sensor
C6689-A2C Used for trace O2 measurements in CO2 containing backgrounds (0.1-100% CO2). CO2 must be present. Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present.
A-2CXL
oxygen sensor
B74033-A2CXL Specially qualified A2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm. Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present.
        A-2Cl: Obsolete, use A-2C
        A-3: Obsolete, use A-5
A-5
oxygen sensor
C6689-A5 Intermittent or continuous monitoring of percent O2 in gas mixtures containing 0-100% CO2. 90% response is time is 45 seconds. Has more tolerance to exposure to air than A-3. No restrictions on CO2 concentration.
B-1
oxygen sensor
C6689-B1 General purpose percent oxygen analysis where fast response is desired (90% in less than 7 seconds). Use B-3 or C-3 where longer life is required and response time is relatively unimportant. May be used to spot check flue gas.
B-2C
oxygen sensor
C6689-B2C General purpose trace O2 analysis for use in inert gas and hydrocarbon streams. Low range limit is 0-10 ppm. May be used in CO2 free gas streams containing highly mobile gases such as H2, He and ethylene.
INSTA TRACE
oxygen sensor
B71875 Special patented construction provides rapid recovery, during initial cell installation, to low PPM levels by reducing the recovery period from several hours to just minutes. Low range limit is 0-10 ppm. Used for trace O2 analysis in inert gas and hydrocarbon streams.
B-2CXL
oxygen sensor
C6689-B2CXL Specially qualified B-2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm. May be used in CO2 free gas streams containing highly mobile gases such as H2, He and ethylene.
B-3
oxygen sensor
C6689-B3 Percent O2 analysis, best compromise between long life and fast response. May be used to spot check flue gas.
B-4C
oxygen sensor
C14613-B4C Trace O2 cell specifically designed for the Model 317EXI. Same performance as the B-2.
B-5
oxygen sensor
C45091-B5 Special application cell (non-standard) where long life and moderately fast response are required; B-5 has a factor of 3x the life of a B-3. Requires 3x the amplifier gain of the B-3. Expected life is 36 months in air.
B-5F
oxygen sensor
C45091-B5F Special application cell (non-standard) where long life and moderately fast response, in the presence of CO2, are required. Uses Type F (acid electrolyte). Requires higher amplifier gain than normal. 90% response time is 13 seconds. Expected life in air is 6 months.
B-7
oxygen sensor
C45091-B7 Special application cell (non-standard) where fast response is required; the B-7 has a factor of 3x the life of a B-1 cell. Requires 3x the amplifier gain of the B-1. Expected life in air is 24 months.
B-7F
oxygen sensor
C45091-B7F Special application cell (non-standard) where moderate life and fast response, in the presence of CO2, are required. Requires higher amplifier gain than normal. 90% response time is 7 seconds. Expected life in air is 3 months.
C-1
oxygen sensor
C6689-C1 Rarely used. Schematic for reference only.
C-2
oxygen sensor
C6689-C2 Rarely used. Schematic for reference only.
C-3
oxygen sensor
C6689-C3 Percent O2 measurements where maximum cell life is desired (high O2 applications). 90% response time is 30 seconds. Expected life in air is 18 months.
C-5
oxygen sensor
C45091-C5 Special application cell (non-standard) where long life is required; the C-5 has a factor of 3x the life of a C-3 cell. Requires 3x the amplifier gain of the C-3. Expected life in air is 54 months.
C-5F
oxygen sensor
C45091-C5F Special application cell (non-standard) where long life, in the presence of CO2, is required. Requires higher amplifier gain than normal. 90% response time is 30 seconds. Expected life in air is 9 months.
C-6
oxygen sensor
C54090-C6 Motion insensitive percent O2 measurements for use in hand held portable monitors. Best cell for OEM safety applications.
E-1
oxygen sensor
C14991-E1 Special cell with performance characteristic of the C-3 with 5x the life. Cell is 2 to 3 times the length of standard MFCs; requires special mounting. Designed for medical oxygen concentrators.
E-2
oxygen sensor
C57283-E2 Long life cell for use is the Model 3290 (for use in unattended air liquefaction nitrogen skids). Has a 3 to 4 years expected life in air. Minimum range 0-1000 ppm.
F-1R C40371-F1R 0-1000 ppm CO in Air Used in Max 5 and 9950 Portable Combustion Analyzers
F-3 C55194-F3 Rarely used. Schematic for reference only.
INSTA TRACE - CO2 B73016 Special patented construction provides rapid recovery, during initial cell installation, to low PPM levels by reducing the recovery period from several hours to just minutes. Used for trace O2 measurements in CO2 containing backgrounds (0-100% CO2) in the 3000T analyzer series. Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present. The INSTA TRACE Micro-fuel Cell oxygen sensor is capable of measuring below 1 ppm of oxygen within 15 minutes of installation.
INSTA TRACE - XL
oxygen sensor
B73592 Special patented construction provides rapid recovery, during initial cell installation, to low PPM levels by reducing the recovery period from several hours to just minutes. Specially qualified sensor to operate in XL model analyzers with a low range limit of 0-1 ppm. Used for trace O2 analysis in inert gas and hydrocarbon streams.
K-1
oxygen sensor
C43832-K1 Smallest Micro-fuel Cell, for use in applications where small size or multiple sensing requirements exist. OEM applications; PC board mountable.
        K-2: Obsolete
L-2C
oxygen sensor
C6689-L2C Used for general purpose trace oxygen analysis in the 3000T analyzer series. Has a 2 year expected life.
L-2CI
oxygen sensor
C6689-L2CI Used in the Model 3000T series for trace O2 measurements; use only in CO2 and H2 background mixtures (e.g. inert gas generators). CO2 concentration should be within +/-20% about some nominal concentration.
S-2C
oxygen sensor
C6689-S2C Trace oxygen cell for use in TurbO2 analyzer. Provides rapid recovery from air calibration (approximately 20 minutes). Low range limit is 0-100 ppm. Has three pin contact system.
Z-2C
oxygen sensor
C6689-Z2C Has the same features as the S-2, except configured for use in the Model 3190. Low range limit is 0-100 ppm. Has normal Micro-fuel Cell

(成都市Teledyne氧气浓度传感器C06689-B1厂家)
供应Teledyne氧气浓度传感器C06689-B1
更多精品
供应C06689-B1氧气传感器

供应C06689-B1氧气传感器

面议
供应Teledyne氧气传感器ClassB-2C

供应Teledyne氧气传感器ClassB-2C

面议
供应Teledyne氧气传感器C06689-A2C

供应Teledyne氧气传感器C06689-A2C

面议
供应Teledyne C06689-A2C氧气传感器

供应Teledyne C06689-A2C氧气传感器

面议
供应Teledyne氧传感器

供应Teledyne氧传感器

面议
供应teledyne传感器

供应teledyne传感器

面议
供应氧气浓度报警器

供应氧气浓度报警器

面议
供应氧气浓度检测仪

供应氧气浓度检测仪

面议
XO-326ALB氧气浓度检测仪

XO-326ALB氧气浓度检测仪

面议
氧气浓度传 氧气传感器 氧浓度传感 city氧 浓度传感器 AO2氧气 汽车氧气传 氧气浓度计 Teledyne氧气浓度传感器C06689-B1厂家 成都市Teledyne氧气浓度传感器C06689-B1厂家
免费入驻
请选择分享的平台

微信

微博

QQ

取消分享
店铺 全部商品 电话咨询